Phe Unit for Air Conditioning Heating for Residential Buildings

Product Details
Customization: Available
Certification: CE, ISO
Application: Heater, Cooler, Vaporizer, Condenser
Still deciding? Get samples of US$ 100/Piece
Request Sample
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
National Award received
This supplier had received national award, you can check the Audit Report for more information
to see all verified strength labels (28)
  • Phe Unit for Air Conditioning Heating for Residential Buildings
  • Phe Unit for Air Conditioning Heating for Residential Buildings
  • Phe Unit for Air Conditioning Heating for Residential Buildings
  • Phe Unit for Air Conditioning Heating for Residential Buildings
  • Phe Unit for Air Conditioning Heating for Residential Buildings
  • Phe Unit for Air Conditioning Heating for Residential Buildings
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Principle
Recuperative Heat Exchanger
Style
Plate Type
Material
Stainless Steel
Gasket Material
NBR, HNBR, EPDM, Fluororubber, Silicon
Plate Material
SS304, SS316L, Smo254,Titanium,Nickle,Hastelloy
Plate Gap Size
Small / Large
Plate Width/Length
Customized
Usage
Cooling/Heating
Industry
Petroleum/Chemical Processing/Food
Transport Package
Plywood Box
Specification
ISO9001: 2008, SGS
Trademark
TRANP
Origin
Guangzhou, China
HS Code
8419500090
Production Capacity
200 Sets/Per Month

Product Description

PHE unit for Air Conditioning Heating for Residential Buildings

What is a heat exchanger unit
Product Description

The efficient and intelligent plate heat exchanger unit is a full automatic, efficient, intelligent and energy-saving product. It's composed of heat exchanger, pump, valve, PLC controlling system, pipes and son on. It's a complete system equipment.
Phe Unit for Air Conditioning Heating for Residential Buildings



What is the structure of HE Unit?

The plate heat exchanger unit essentially consists of a heat exchanger, a circulating pump, a make-up pump, an electric cabinet, a filter, a base, a pipeline, valves and instruments and may be provided with components such as an automatic constant-pressure water make-up device, a water treatment device, a water tank, a pump variable-frequency controller, a temperature control valve and a remote communication controller to form a complete heat exchange station.

With characteristics of standard and modular design, complete configuration, easy installation, high efficiency and energy saving, it is widely used in central heating systems, central air-conditioning systems, domestic water systems, enterprises' process water systems, etc.
Phe Unit for Air Conditioning Heating for Residential Buildings


 
                                                 
Plates and Gaskets 


The plate heat exchanger's plate materials and corresponding applicable places are given in Table 1 and its gasket materials and corresponding applicable places in Table 2 for your reference.
Phe Unit for Air Conditioning Heating for Residential Buildings
Phe Unit for Air Conditioning Heating for Residential Buildings


Table 1    Plate Materials
Material name Thickness(mm) Material grade Applications
Stainless steel 0.5-0.8 304,321,316,316L
Places with serious corrosion caused by acid or base mediums and places not suitable for chloride ions
Commercial pure titanium 0.5-0.8 Ti Alkali or salt making places, sea water desalination places, low-temperature places, freezing places or places with chloride-ion corrosion
Nickel 0.5-0.8 Ni Places resistant to corrosion, hot alkali liquor corrosion, neutral solutions or subacid solutions
Acid-resistant steel 0.5-0.8 RS-2, SM0254, HC-276 Sulfuric acid field and the fields with acid corrosion

Table 2   Gasket Materials
Material name Code Applicable temperature Applications
NBR N -20~110ºC Water, non-polar oil, mineral oil, lubricating oil, silicon oil, etc.
EPDM E -20~150ºC Steam, water, ozone, polar chemical mediums, alcohol, weakacids, weak bases, salt solutions, etc.
Chloroprene rubber C -40~100ºC Ammonia, mineral roil, lubricant, freon, etc.
Fluororubber F 0~180ºC Inorganic acids, bases, mineral oil, halohydrocarbon and oxidant
Silicon rubber Q -40~200ºC Food field, etc.

About Us
Company Profile

Phe Unit for Air Conditioning Heating for Residential BuildingsPhe Unit for Air Conditioning Heating for Residential BuildingsPhe Unit for Air Conditioning Heating for Residential BuildingsPhe Unit for Air Conditioning Heating for Residential BuildingsPhe Unit for Air Conditioning Heating for Residential BuildingsPhe Unit for Air Conditioning Heating for Residential Buildings




For more information, feel free to contact us !
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier